TORNADO CO., LTD WEBJET 128 Card Type ISDN TA Chip Set Unidentified I/O Options RJ-45 ISDN BRI U interface, 9-pin DTE port, power, microphone in, speaker out ISDN Rate 230.4Kbps ISDN Modulation Protocol PPP, MLPPP, V.120 Error Correction/Compression Unidentified Data Bus External [Image] CONNECTIONS Function Label Function Label ISDN BRI interface (RJ-45) CN1 9-pin DTE port CN4 Microphone in CN2 Power CN5 Speaker out CN3 Power switch SW1 DIAGNOSTIC LED(S) LED Color Status Condition DATA Unidentified On DTR is high DATA Unidentified Blinking Serial data transfer active DATA Unidentified Off Serial data transfer not in progress B1 Unidentified On B-channel 1 data call connected B1 Unidentified Off No activity on B-channel 1 B2 Unidentified On B-channel 2 data call connected B2 Unidentified Off No activity on B-channel 2 PWR Unidentified On Power is on PWR Unidentified Off Power is off SUPPORTED COMMAND SET Basic AT Commands AT, ‘+++’, A/ A, E, Q, V, W, X &F, &V S Registers S0, S2, S3, S4, S5, S7, S25 Note: See MHI Help File for full command documentation. Proprietary AT Command Set COMMUNICATIONS MODE Type: Configuration Format: AT [cmds] &M n [cmds] Description: Selects communications mode Command Mode &M0 Asynchronous mode &M1 Synchronous connect mode and asynchronous off-line command mode. &M2 Synchronous connect mode and asynchronous off-line command mode and set DTR high. COMMUNICATIONS MODE Type: Configuration Format: AT [cmds] &Q n [cmds] Description: Selects communications mode options Command Mode &Q0 Asynchronous mode, serial port speed follows connect speed. &Q1 Asynchronous off-line command mode and synchronous connect mode. &Q2 Asynchronous off-line command mode - modem autodials first number in directory, then synchronous connect mode. &Q3 Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR. &Q4 Auto-synchronous mode &Q5 Error correction mode DATA CARRIER DETECT (DCD) Type: Configuration Format: AT [cmds] &C n [cmds] Description: Selects whether the DCD option is enabled or disabled Command Function &C0 DCD enabled &C1 DCD enabled after carrier signal detected &C2 DCD enabled when on-line, low at loss of carrier, enabled again at idle DATA SET READY (DSR) Type: Configuration Format: AT [cmds] &S n [cmds] Description: Selects DSR options Command Function &S0 DSR forced high &S1 DSR high only while modem is connected &S2 DSR high only while modem is connected DATA TERMINAL READY (DTR) Type: Configuration Format: AT [cmds] &D n [cmds] Description: Selects modem response to DTR Note: The action each variant of &D causes depends on the setting of &Q &Q Setting &D0 &D1 &D2 &D3 &Q0, &Q5 Command 0 Command Command Command 4 1 2 &Q1 Command 2 Command Command Command 4 1 2 &Q2 Command 2 Command Command Command 2 2 2 Command Function Command 0 Modem does not respond to DTR Command 1 Modem goes to command mode after DTR goes is off Command 2 Modem goes to command mode and disconnects (hangs up) after DTR goes off; Auto-Answer is disabled. Command 3 Modem is initialized after DTR goes off DIAL Type: Immediate Format: AT [cmds] D<#> [cmds] Description: Dials telephone number according to any modifiers included in the string FLOW CONTROL Type: Configuration Format: AT [cmds] &K n [cmds] Description: Enables flow control options Command Function &K0 Flow control disabled &K1 RTS to CTS flow control enabled &K2 XON/XOFF flow control enabled &K3 RTS/CTS flow control enabled &K4 XON/XOFF flow control enabled HOOK CONTROL Type: Immediate Format: AT [cmds] H n [cmds] Description: Selects whether the modem is on-hook or off-hook Command Function H0 Modem commanded to go on-hook (hang-up) ON-LINE Type: Immediate Format: AT [cmds] O n [cmds] Description: Controls on-line command (data transmission) state options. Note: The O command must be placed at the end of the command string. Command Function O0 On-line command mode with no retraining enabled PROTOCOL SELECTION Type: Configuration Format: AT [cmds] &O n [cmds] Description: Selects active protocol Command Mode &O7 PPP, 1 x B &O8 V.14, 1 x B &O9 V.110, 1 x B &O10 V.120, 1 x B &O13 Multi Link V.120, 2 x B &O16 GCI-speech, 2 x B &O18 GCI-data, 2 x B &O27 Multi Link PPP, 2 x B REPORT INFORMATION Type: Immediate Format: AT [cmds] I n [cmds] Description: Displays information requested Command Function I0 Reports hardware identification I1 Reports ROM checksum I2 Tests and reports ROM checksum I3 Reports product name and software revision I4 Reports manufacturer information I5 Reports protocol options I8 Reports Euro-ISDN software version RESTORE PROFILE ON POWER-UP Type: Configuration Format: AT [cmds] &Y n [cmds] Description: Restores a selected profile into the active profile on power-up (hard reset). RTS/CTS Type: Configuration Format: AT [cmds] &R n [cmds] Description: Command function currently unidentified SOFT RESET Type: Immediate Format: AT [cmds] Z n [cmds] Description: Restores modem profiles previously saved in non-volatile RAM using the &W command. STORE ACTIVE PROFILE Type: Configuration Format: AT [cmds] &W n [cmds] Description: Writes the values for the active profile into the non-volatile RAM EXTENDED AT COMMANDS CONFIGURATION PROFILES Type: Immediate Format: AT [cmds] /S [cmds] Description: Displays active and stored configuration profiles SPECIAL COMMANDS PROTOCOL SELECTION Type: Configuration Format: AT [cmds] #CH= n [cmds] Description: Selects active protocol Command Mode #CH=7 PPP, 1 x B #CH=8 V.14, 1 x B #CH=9 V.110, 1 x B î V.120, 1 x B #CH=13 Multi Link V.120, 2 x B #CH=16 GCI-speech, 2 x B #CH=18 GCI-data, 2 x B #CH=27 Multi Link PPP, 2 x B REMOTE NUMBER SELECTION Type: Configuration Format: AT [cmds] #REMNBRC= n [cmds] Description: Selects remote control number REMOTE PASSWORD SELECTION Type: Configuration Format: AT [cmds] #PASSRC= n [cmds] Description: Selects remote control password RING MODE Type: Configuration Format: AT [cmds] #RM= n [cmds] Description: Selects ring mode Command Mode #RM0 Selects ring mode by subnumber or MSN #RM1 Pass on call to active profile SOFT RESET Type: Immediate Format: AT [cmds] #Z n [cmds] Description: Restores modem profiles previously saved in non-volatile RAM using the &W command. STORED PROFILES Type: Immediate Format: AT [cmds] #V [cmds] Description: Displays list of stored parameters in short form S(STATUS) -REGISTERS ACTIVE PROFILE Type: Register Format AT [cmds] S110= n [cmds] Range: 0-255 Unit: Bit-mapped Description: Selects active profile AUTOBAUD Type: Register Format AT [cmds] S124= n [cmds] Description: Enables/disables autobaud function Command Function S124=0 Autobaud disabled S124=1 Autobaud enabled BIT-MAPPED REGISTER S112 Format: AT [cmds] S112= n [cmds] Range: Unidentified Unit: Bit-mapped Description: Controls ring message format Bit Value Function 0 0 Standard AT RING message format (RING) 1 Extended AT RING message format (RING J 1 0 Extended result codes disabled 1 Extended result codes enabled 2 0 Not used 3 0 Standard AT format 1 Extended AT format 6 - 4 0 Not used 7 0 Additional service messages disabled 1 Additional service messages enabled DTR COMMAND Type: Register Format AT [cmds] S123= n [cmds] Description: Enables &D command Command Function S123=0 &D enabled for DTR functions S123=1 DTR ingnored. &D command disabled EXTENDED RESULT CODES Type: Register Format AT [cmds] S95= n [cmds] Range: 0-255 Unit: Bit-mapped Description: Works in combination with the W n command to enable extended result codes. Features enabled by S95 take precedence over the options selected by W n . Bit Value Function 0 0 CONNECT result code reports DTE speed. 1 CONNECT result code reports line speed instead DTE speed. 1 0 Verbose CONNECT result codes display DTE or 1 line speed only. Adds "/ARQ" to all verbose CONNECT result codes except "NONE." 2 0 CARRIER result codes disabled. 1 CARRIER result codes enabled. 3 0 PROTOCOL result codes disabled. 1 PROTOCOL result codes enabled. FACTORY DEFAULT PROFILE Type: Configuration Format: AT [cmds] S121= n [cmds] Range: 0-255 Description: Sets values in active profile to values found in the default profile Command Function S121=0 Retrieve factory settings and restart S121=255 Disabled FLOW CONTROL Type: Register Format AT [cmds] S39? [cmds] Description: Displays the current flow control Value Meaning 0 Flow control disabled 3 RTS/CTS flow control enabled 4 XON/XOFF flow control enabled PROTOCOL SERVICE Type: Register Format AT [cmds] S111= n [cmds] Description: Selects options for protocol service Command Function 1 Voice service 2 Data modem service 3 Raw data service 4 Group 3 fax service 5 V.14 7 PAD service 8 V.120 service 10 Synchronous relay service RING MESSAGE TIMER Type: Register Format AT [cmds] S117= n [cmds] Range: 0-255 Unit: 1 second Description: Maximum duration allowed between two consecutive RING messages Note: S117=0 allows for a single RING message only SERIAL ASYNCHRONOUS RATE & CLOCK SELECTION Type: Register Format AT [cmds] S114= n [cmds] Description: Selects sserial asynchronous speed & clock selection Command Function S114=0 External clock source S114=1 1200bps S114=2 2400bps S114=3 300bps S114=4 4800bps S114=7 7200bps S114=9 9600bps S114=12 1200bps S114=14 14.400bps S114=19 19.2Kbps S114=24 2400bps S114=28 28.8Kbps S114=38 38.4Kbps S114=48 4800bps S114=20 57.6Kbps S114=72 7200bps S114=75 75bps S114=96 9600bps S114=115 115.2Kbps S114=255 Internal clock source SOFT RESET Type: Immediate Format: AT [cmds] S122= n [cmds] Description: Restores modem profiles previously saved in non-volatile RAM using the &W command. Command Function S122=0 Restore setting S122=255 Disabled